Rated Temperature: -60 C to +180 C
Voltage: 5kv-30kv
Conductors: Tin-coated copper wire
Insulator: Silicone Rubber
Used for high voltage motor leading cable, Power transmission etc.
section |
conductor |
insulation |
wire OD |
conductor resistance |
structure |
Diameter |
nominal thick |
min. thick |
nominal |
allowance |
20 C degree |
mm² |
No./mm |
mm |
mm |
mm |
mm |
mm |
Ω/KM |
0.75 |
24/0.20 |
1.15 |
2.3 |
1.97 |
5.75 |
±0.25 |
26.7 |
1.0 |
32/0.20 |
1.34 |
2.3 |
1.97 |
5.95 |
±0.25 |
20 |
1.5 |
30/0.25 |
1.60 |
2.5 |
2.15 |
6.60 |
±0.30 |
13.7 |
2.0 |
41/0.25 |
1.90 |
2.5 |
2.15 |
6.90 |
±0.30 |
9.9 |
2.5 |
49/0.25 |
2.0 |
2.8 |
2.42 |
7.60 |
±0.30 |
8.21 |
4 |
56/0.30 |
2.70 |
2.8 |
2.42 |
8.30 |
±0.30 |
5.09 |
6 |
84/0.30 |
3.30 |
3.0 |
2.6 |
9.30 |
±0.30 |
3.39 |
10 |
84/0.40 |
4.60 |
3.0 |
2.6 |
10.60 |
±0.30 |
1.95 |
16 |
126/0.40 |
5.80 |
3.2 |
2.78 |
12.20 |
±0.30 |
1.24 |
25 |
196/0.40 |
7.30 |
3.2 |
2.78 |
13.70 |
+0.40 |
0.795 |
-0.30 |
35 |
276/0.40 |
8.60 |
3.4 |
2.96 |
15.40 |
+0.40 |
0.565 |
-0.30 |
50 |
396/0.40 |
10.70 |
3.4 |
2.96 |
17.50 |
+0.40 |
0.393 |
-0.30 |
70 |
360/0.50 |
12.40 |
3.6 |
3.14 |
19.60 |
+0.50 |
0.277 |
-0.30 |
95 |
475/0.50 |
14.50 |
3.6 |
3.14 |
21.70 |
+0.50 |
0.21 |
-0.30 |
120 |
608/0.50 |
16.00 |
4.0 |
3.5 |
24.00 |
+0.50 |
0.164 |
-0.30 |
150 |
756/0.50 |
18.00 |
4.2 |
3.68 |
26.40 |
+0.60 |
0.132 |
-0.30 |
185 |
925/0.50 |
20.00 |
4.5 |
3.95 |
29.00 |
+0.60 |
0.108 |
-0.30 |
240 |
1221/0.50 |
23.00 |
4.8 |
4.22 |
32.60 |
+0.60 |
0.0817 |
-0.30 |